[Product Profile]
MT1601 reluctance sensing electronic water meter module uses low-power processor, non-contact multi-phase magnetic resistance sensor (AMR) to detect impeller rotation, and has no mechanical counter electronic water meter module. It has the advantages of high metering accuracy, small starting flow, wide range, etc. It uses intelligent electronic curve compensation technology to shorten the calibration time.
[Product Characteristics]
AMR reluctance angle phase detection metering technology does not need mechanical counter assembly to directly sample impeller rotation angle calculation amount, high metering accuracy, low starting flow;
Supporting positive/reverse flow measurement;
Broad range measurement: 5-digit integer + 5-digit decimal display;
LCD Chinese/English LCD display cumulative usage, alarm information, etc.
Large storage capacity: frozen data for 12 months, frozen data for 30 days and current cumulative usage;
Circuit design with ultra-low power consumption, battery life > 7 years;
Early warning of magnetic interference, LCD displays "interference" signal when disturbed by external magnetic field;
Early warning of battery undervoltage;
Data outage protection function.
[Technical parameters]
No. | Performance | Parameter |
1 | Diameter of water meter | DN15-DN200 |
2 | Range ratio | R200\R160\R125\R100\R80 |
3 | Measurement accuracy | 0.01L |
4 | Maximum dosage range | 999999.9999m³ |
5 | communication interface | RS485/M-BUS |
6 | Communication rate | 1200 \2400\4800\ 9600bps(default 2400bps) |
7 | Battery type | Panasonic lithium manganese battery 3V |
8 | Bus operating voltage | MBus interface: 36V RS485 interface: 12V |
9 | Electric current | Battery quiescent current ≤ 8ua; Bus static current ≤ 2mA, bus working current ≤ 20mA; |
10 | Protocol type | cjt-188 / Modbus / user defined protocol; |
11 | Electromagnetic compatibility (EMC) | Electrostatic protection grade: contact ≥ ± 6kV, air ≥ ± 8Kv; Surge protection level: ± 2KV; Fast transient pulse group: ± 2KV; |
12 | Operation temperature | -5℃~+55℃; |
13 | Storage environment | temperature:-25℃~+55℃;humidity:0~93%±3%RH; |
14 | Power supply mode | Power is supplied by bus during communication and battery during metering |