[Product Profile]
MT1903 Magnetoresistance Sensing Electronic Water Meter Module is a low-power processor, non-contact multiphase magnetoresistance sensor (AMR) to detect impeller rotation, no mechanical counter, valve-controlled electronic water meter module. It has the advantages of high metering accuracy, small starting flow, wide range, etc. It uses intelligent electronic curve compensation to shorten the calibration time.
[Functional characteristics]
Adopt reluctance angle phase detection metering technology, without counter components, directly sample the calculation amount of impeller rotation angle, with high metering accuracy and low starting flow;
Supporting positive/reverse flow measurement;
Broad range measurement: 5-digit integer + 5-digit decimal display;
LCD Chinese/English LCD display cumulative usage, alarm information prompts, etc.
Large storage capacity: frozen data for 12 months, frozen data for 30 days and current cumulative usage;
Circuit design with ultra-low power consumption, battery life > 7 years;
Early warning of magnetic interference: LCD displays "interference" signal when external magnetic interference occurs;
Early warning of battery undervoltage;
Pre-payment and post-payment management and real-time settlement;
Waterfall alarm function;
Data outage protection function;
Function of valve control;
Backwater function: partial backwater operation can be carried out after the water meter is filled;
Function of zero clearing of recharge data in the table.
[Technical parameters]
No. Performance Parameter 1 Diameter of water meter DN15-DN200 2 Range ratio R200\R160\R125\R80 3 Measurement accuracy 0.01L 4 Maximum dosage range 999999.9999m³ 5 communication interface MT2002-RS185/MT1903-M-BUS/TTL 6 Communication rate 1200 \2400\4800\ 9600bps(default 2400bps) 7 Battery type Panasonic lithium manganese battery 3V 8 Bus operating voltage MBus interface: 36V RS485 interface: 12V 9 electric current Battery quiescent current ≤ 8ua;
Bus static current ≤ 2mA, bus working current ≤ 20mA;10 Protocol type cjt-188 / Modbus / user defined protocol; 11 Electromagnetic compatibility (EMC) Electrostatic protection grade: contact ≥ ± 6kV, air ≥ ± 8Kv;
Surge protection level: ± 2KV;
Fast transient pulse group: ± 2KV;12 operation temperature -5℃~+55℃; 13 Storage environment temperature:-25℃~+55℃;humidity:0~93%±3%RH; 14 Power supply mode Power is supplied by bus during communication and battery during metering