[product introduction]
MT2002 magnetoresistive sensing electronic water meter module is an electronic water meter module with valve control function, which uses low-power processor and non-contact polyphase magnetoresistive sensor (AMR) to detect impeller rotation. It adopts the advantages of high measurement accuracy, small starting flow and wide range. It adopts intelligent electronic curve compensation to shorten the calibration time.
[functional features]
● magnetoresistive angle phase detection and metering technology is adopted, without counter components, directly sampling impeller rotation angle to calculate consumption, with high metering accuracy and low starting flow;
● support forward / reverse flow metering;
● wide range measurement: 5-digit integer + 5-digit decimal display;
● LCD Chinese / English LCD display cumulative consumption, alarm information prompt, etc;
● large storage capacity: 12 months of monthly frozen data, 30 days of daily frozen data and current cumulative consumption;
● ultra low power consumption circuit design, battery life ≥ 7 years;
● magnetic interference warning: in case of external magnetic interference, LCD displays "interference" signal;
● early warning of battery undervoltage;
● prepayment and post payment management, real-time settlement;
● residual water volume alarm function;
● data power-off protection function;
● valve control function;
● water return function: after the water meter is recharged, partial water return operation of the water meter can be carried out;
● reset function of recharge data in the table.
No. | Performance | Parameter |
1 | Applicable water meter diameter | DN15~DN200 |
2 | Range ratio | R200\R160 |
3 | Measurement accuracy | 0.01L |
4 | Maximum usage display range | 999999.9999m³ |
5 | communication interface | MT2002-RS485/M-BUS/TTL |
6 | Communication rate | 1200 \2400\4800\ 9600bps(default2400bps) |
7 | Battery type | Panasonic lithium manganese battery 3V |
8 | Bus operating voltage | MBus interface: 36V RS485 interface: 12V |
9 | Electric current | Battery quiescent current ≤ 8ua; Bus static current ≤ 2mA, bus working current ≤ 20mA; |
10 | Protocol type | cjt-188 / Modbus / user defined protocol; |
11 | Electromagnetic compatibility (EMC) | Electrostatic protection grade: contact ≥ ± 6kV, air ≥ ± 8Kv; Surge protection level: ± 2KV; Fast transient pulse group: ± 2KV; |
12 | Operation temperature | -5℃~+55℃; |
13 | Storage environment | temperature:-25℃~+55℃;humidity:0~93%±3%RH; |
14 | Power supply mode | Power is supplied by bus during communication and battery during metering |